Home Electronics Single section mains cycle skipping controller sans harmonics

Single section mains cycle skipping controller sans harmonics

0
Single section mains cycle skipping controller sans harmonics

[ad_1]

In electrical heating functions, resistive heaters are powered via section angle-controlled SCR/triac circuits to differ the utilized voltage/energy to keep up the required temperature.

Section angle management produces a number of harmonics resulting in energy line disturbances.

Wow the engineering world along with your distinctive design: Design Concepts Submission Information

Determine 1’s circuit offers a easy and cost-effective answer with out introducing harmonics. This controller skips a sure variety of energy cycles in between, to differ energy to the warmers.

Improved Power Efficiency and AI Inference in Autonomous Systems

03.26.2024

Leveraging Advanced Microcontroller Features to Improve Industrial Fan Performance 

03.21.2024

FerriSSD Offers the Stability and Data Security Required in Medical Equipment 

03.18.2024

Determine 1 Circuit schematic of mains cycle skipping controller, this controller skips a sure variety of energy cycles in between, to differ energy to the warmers.

On this typical design, 10 full cycles are taken as base. Timer U3 (555) via R2, R4, and C1 decides this by giving output pulses with an interval of  200 ms, which is the width of 10 full AC cycles of a 50 Hz AC mains (for a 60 Hz mains, this can be 166.6 ms). These pulses set off U4 (555) monostable to supply pulses with an adjustable width inside 200 ms, by adjusting potentiometer RV1. This pulse practice controls an optotriac with zero cross detector U2 (MOC3033) to set off triac U1 (BTA25-600BW). The triac conducts during “off pulse widths” produced by U4. Thus, these conduction intervals permit the chosen variety of voltage cycles to go via and impress on load. Throughout “on pulse widths”, the triac doesn’t conduct and skips the voltage cycles. Simulated waveforms might be seen in Determine 2 with two full cycles being skipped and Determine 3 with 5 full cycles being skipped.


Determine 2
Simulated waveforms with the U3 timer output (yellow), U4 timer output (blue), and heater voltage (pink). Eight full cycles are impressed on load, skipping two full cycles as determined by the RV1 potentiometer place.

Determine 3 Simulated waveforms with the U3 timer output (yellow), U4 timer output (blue), and heater voltage (pink). 5 full cycles are impressed on load, skipping 5 full cycles as determined by one other RV1 potentiometer place.

For instance, if a 40 ms width is chosen by RV1, which corresponds to 2 full cycles of a 50 Hz mains, the triac won’t conduct for two voltage cycles and can conduct for 8 full cycles and go to the load. Thus, two cycles are skipped. This operation repeats. Thus, load energy is managed by skipping a particular variety of voltage cycles. As AC cycles handed to load are full cycles, undesirable harmonics are eradicated.

Usually such controllers are realized with an MCU and software program, the novelty of this circuit realizing the  identical operate with out utilizing the MCU, thus making it easy with low value elements.

Jayapal Ramalingam has over three many years of expertise in designing electronics methods for energy & course of industries and is presently a contract automation guide.

 Associated Content material

[ad_2]